Jitter in Clock Sources
Continuous advances in high-speed communication and measurement systems require higher levels of
performance from system clocks and references. Performance acceptable in the past may not be sufficient
to support high-speed synchronous equipment. Perhaps the most important and least understood measure
of clock performance is jitter.
The purpose of this discussion is fourfold.
- To define jitter intuitively, and discuss it's properties.
- To explain how jitter degrades system performance.
- To describe various practical methods of measuring jitter, including the relevance and ease of each method.
- Offer guidelines for specifying high-speed clocks and related devices.
Jitter Defined:
- Jitter: "Short-term variations of the significant instants of a digital signal from their ideal
positions in time" (ITU).
The expected edges in a digital datastream never occur exactly where desired. Defining and measuring
the timing accuracy of those edges (jitter) is critical to the performance of synchronous communication
systems.
Digital Waveform with Jittered Edges
Figure 1
Definition of terms:
- Jitter expressed in Unit Intervals: A single unit interval is one cycle of the clock frequency.
This is the normalized clock period. Jitter expressed in Unit Intervals describes the magnitude
of the jitter as a decimal fraction of one unit interval.
- Jitter expressed in degrees (deg.): Jitter expressed in degrees describes the magnitude of the
jitter in units of deg. where one cycle equals 360 deg.
- Jitter expressed in absolute time: Jitter expressed in units of time describes the
magnitude of the jitter in appropriate orders of magnitude, usually picoseconds.
- Jitter expressed as a power measurement is described in units of radians or unit intervals squared.
Often expressed in dB relative to one cycle-squared
(From Bellamy) [1]
- Pattern Jitter: Pattern dependent jitter. Sometimes referred to as flanging. Not random in
nature. Generally a result of subharmonics. When viewed in the time domain, it is seen as multiple
modes of jitter. Pattern jitter is deterministic, it is a phenomenon that may be attributed to a
unique source. All other jitter referred to in this discussion is stochastic in nature, and may
only be described as a random variable with respect to time.
For example:
Assume a clock rate of 155.52 MHz. One unit interval would be equal to the period of the signal, 1/155.52
MHz = 6.43 nsec. = 360 deg.
Assume 100 ps Pk-Pk of jitter.
100 Ps of jitter = .01555 unit intervals (UI) of jitter = 5.598 deg. of jitter. (All Pk-Pk)
All three measurements describe the same amount of jitter.
For jitter power, rms (one sigma, ) measurements are used. For the above
case, we approximate Pk-Pk as 7 , or 7 times the RMS value, placing the rms.
jitter power at .0000049 UI2. {(.01555/7)2 . Expressed in dB, relative to one
unit interval, jitter power in this case would be 10log (.0000049)= -53.1 dBui. As will be
seen later, jitter can be derived from power spectral density (phase noise) measurements. Table 1
relates various measures of jitter in a 155.52 MHz system clock.
|
Pk-Pk Jitter in Seconds
|
Degrees
|
Unit Interval
|
Unit Interval
|
Jitter Power
|
| 6.43E-09=one cycle |
Degrees (Pk-Pk) |
Pk-Pk Units |
RMS Units |
dBui |
| |
normalized |
normalized |
normalized |
|
| |
|
|
|
|
| |
|
|
|
|
| 1.00E-10 |
5.60 |
0.015552 |
0.0022217 |
-53.07 |
| |
|
|
|
|
| 2.00E-11 |
1.12 |
0.003110 |
0.0004443 |
-67.05 |
| |
|
|
|
|
| |
|
|
(1/7 of Pk-Pk |
|
| |
|
|
approximation) |
|
Table 1
Jitter Bandwidth and Spectral Content
The displacement of edges in Fig.1 is a result of noise. Noise has spectral content as well as power.
Consequently, the edge jitter in Fig.1 also has spectral content. The edges in Figure 1 vary randomly
with time, however the noise that causes the jitter is not necessarily uniform over all frequencies.
Jitter due to 10 kHz noise could be greater or less than jitter due to 100 kHz noise. Spectral content
of clock jitter differs greatly depending on the technique used to generate the clock. Measured jitter
also varies with measurement technique and jitter bandwidth. Improperly specified or measured jitter
might result in unnecessary costs, or poor system performance.
See references [2,3] for additional
information on defining and specifying jitter in telecom systems. Jitter characteristics of various
clock sources is discussed later in this article.
How Does Jitter Effect System Performance
The effects of jitter on communication systems are well beyond the scope of this discussion. Refer to
references [1,4] for a more thorough treatment.
A simple discussion may help to understand the deleterious effects of jitter in digital systems.
Every bit of data transmitted over synchronous communication systems is sampled for its value at the
receiver. The sampled data can only have the value of logical one or zero. The optimum point for sampling
data is at the center of each transmit clock cycle. In order to perform this function, the receiver
aligns its own clock with the clock used to transmit the data. Figs.2, a, b, and c represent ideal,
typical, and corrupted datastreams respectively. Commonly referred to as an "eye diagram" each graph is a
cumulative graphical portrait of the edge placement due to noise or jitter. Ideally, sampling occurs at
the center of the "eye". As edge jitter increases, the apparent eye begins to close. As a result,
the likelihood of an error, i.e.
. mistaking a logical one for a zero is more likely. Jitter due to
oscillator noise is only one source of jitter in a telecom system. System designers must consider many
sources of noise in telecom systems. The jitter introduced by clock sources is one component of noise,
and becomes only one part of an "error budget" that must be weighed against performance
requirements and cost.
Measurement Techniques
Time Domain Measurements
Edge to Edge Jitter Using a Delay Line
A true measure of clock jitter is the accurate position of clock edges over time. The most direct
method of examining the placement of edges would be to look at the edges using an oscilloscope.
Unfortunately, using standard oscilloscope techniques it is impossible to identify individual clock
edges in absolute time. Any jitter measured with a standard oscilloscope is due to trigger instability.
As a result, direct waveform measurements using an oscilloscope (even a very good oscilloscope) are
not valid measurements of jitter. An additional technique is used to locate the reference edge,
discriminate with time, and examine the jitter on following edges. Figure 3 illustrates this method
with a typical configuration.

Figure 3
The output of the unit under test is fed into splitter/delay line. The non-delayed output of the
splitter is fed to the external trigger input of the oscilloscope (a CSA-803 in this case). The
delayed output of the DL-11 is connected to the input of the oscilloscope. By examining the clock-stream
at a time after the trigger equal to the delay used (in this case, 47 nsec), the trigger-edge is located.
After the triggered edge has been identified, the next edge is examined. A histogram plot is then
produced of the measured jitter of the second edge.
A CSA-803 is used for its statistical and histogram
capabilities. This is a useful technique limited by the length of the delay line and the speed/sensitivity
of the oscilloscope. For all frequencies greater than 1/(2 d), the measurement is limited by the noise of the oscilloscope. Below
1/(2 d), the sensitivity
drops approximately 20 dB/decade. For the 47-nsec delay shown in fig 3, the corner frequency occurs
at 3.3 MHz. All jitter due to frequencies above 3.3 MHz can be resolved to approximately 5 ps using the
CSA-803. Jitter at 330 kHz can not be resolved below 50 ps. In a similar manner, jitter at 33 kHz can
not be measured below 500 ps. Figure 4 is a plot of RMS jitter sensitivity using a 47-nsec delay line.
It is critical to understand the advantages and limitations of this measurement method. For the
numerical example given, low frequency jitter below 300 kHz would not be seen. Conversely, jitter due
to sidebands 3.0 MHz offset or more could easily be identified. This test method is appropriate when
measuring oscillators that employ direct frequency multiplication or where low frequency jitter is not
considered. (See previous description of Pattern Jitter).

Sens(f)=
Where:
Sens(f)=jitter sensitivity
d=amount of delay used
f=the jitter frequency to be measured
r=oscilloscope resolution
Fig. 4
Jitter Measurements Using Phase Locked Loops
It was noted that the length of the delay line limits resolution when measuring edge jitter. In order
to measure jitter below 100 Hz offset, one needs merely to order up about three hundred miles of very
low loss delay line. In lieu of such a device, phase locked loops are used for a variety of noise
measurements.

Fig. 5
Figure 4 shows the basic elements of a phase locked loop (PLL) used to measure the noise of a clock source.
Gardner [5],
Best [6], and
Woolover [7] are three excellent references
for understanding PLLs. Some key loop requirements follow:
- The PLL loop bandwidth is a critical parameter for successful measurements. The system will
only measure jitter frequencies outside (higher than) the loop bandwidth. It is recommended that
the loop bandwidth be set to a maximum of 1/10 the lowest jitter frequency of interest.
- Loop damping must be set to at least 5 in order to reduce jitter peaking in the PLL. Jitter
peaking will increase measured jitter.
- The measurement filter corresponds to jitter bandwidths recommended in Bellcore and ITU
specifications. Refer to [2,3] for a list of jitter bandwidths and specifications. Band limiting
needs to be defined as a pre-condition for any valid measurement.
- The output of the phase detector (PD) is a varying DC signal that is proportional to the varying
phase due to jitter. It is necessary to know the gain constant (Kd) of the PD in volts/radian in
order to quantify the detected jitter. For example, a phase detector with a Kd equal to 1 millivolt
per degree will have a peak to peak output of 10 mV for an oscillator with 10 deg. Pk-Pk jitter.
It may be necessary to inject a known amount of jitter in order to calibrate the system for accurate
measurements.
Jitter Measurements
Using Phase Locked Loops: Interpreting the Data.
- In The Time Domain,
the output signal of the phase detector in Figure 5 contains a wealth of information about the jitter
of the measured clock. Direct examination of the signal using an oscilloscope can show Pk-Pk jitter.
A true RMS voltmeter can be used to measure RMS (one sigma) jitter. For these measurements, it is
critical that the measurement filters used represent the band of jitter frequencies of interest. It
would make no sense to measure noise from dc to 10 MHz when a bandwidth of 10 kHz to 1 MHz is required.
Oscilloscopes with histogram and statistical capabilities are useful for characterizing the measured
jitter.
- In the Frequency Domain,
the spectrum of the output signal from the phase detector in Figure 4 represents the spectrum and
relative amplitude of jitter in the frequency domain. Examining the spectrum with a low frequency
or FFT analyzer gives the most intuitive picture of clock jitter in terms of spectrum. By integrating
the signal jitter spectrum over the frequency of interest, it is possible to derive the RMS jitter of
the clock. This is the most accurate and unfortunately the most cumbersome method for characterizing
jitter, requiring specialized test equipment. A numerical example is shown below and included in
Appendix A.
Specifying Jitter Performance
Good jitter performance and low cost are not mutually exclusive as long as:
- The system requirements for jitter are defined in terms of amplitude and spectrum.
- The method used to generate the clock output frequency is optimal for the application.
System Requirements:
Although it is impossible to address all possible variations, some general recommendations based on years
of oscillator manufacturing may be helpful.
While not a complete survey of all applications, Table 1 is a starting point for specifying oscillator
performance. Jitter above 1 kHz is considered high frequency jitter.
Application Performance Requirements
| System Application |
Degrees of Difficulty |
Low Frequency |
High Frequency |
Possible |
| |
|
Jitter Importance |
Jitter Importance |
Type |
| |
|
|
|
see Table 2 |
| Radar |
Very Difficult Noise Application |
Critical |
Critical |
A, B, C, D |
| |
|
|
|
|
| Ultrasound/MRI |
Very Difficult Noise Application |
Critical |
Critical |
A, B, C, D |
| |
|
|
|
|
| Navigation/GPS |
Difficult Noise Application |
Critical |
High |
A, B, C, D |
| |
|
|
|
|
| Transmission Systems (telecom) |
|
|
|
|
| Public Network |
Moderate Noise Application |
Moderate |
Moderate |
A, B, C, D |
| Private Network (LAN) |
Generally Easiest Application |
Low |
Low |
A, B, F |
| |
|
|
|
|
| Frequency Synthesis (see note 1) |
|
|
|
|
| Low Freq. Reference |
|
Moderate-Critical |
Moderate-Low |
A, B, C |
| High Frequency Source |
|
Moderate-Low |
Moderate-Critical |
D, E, F |
Table 1
Note 1: Overall jitter performance is highly dependent on loop parameters.
Clock Generation:
Various methods may be employed to generate high frequency clocks.
Performance may vary significantly based on the technique used. Below 20 MHz, it can be assumed that
direct crystal frequency generation is sufficient for all but the most critical requirements. Low
Noise options should be considered for low jitter applications for 20 MHz and above. Table 2 may be
used as a starting point to select a cost-effective solution. Variations and combinations of methods
listed in table 2 could also be optimal solutions.
Jitter Performance
| Technique |
Cost |
LF Jitter |
HF Jitter |
Comments |
Type |
| |
1 is lowest |
1 is best |
1 is best |
|
|
| |
3 is highest |
3 is worst |
3 is worst |
|
|
| Direct Clock/TCXO |
1 |
2 |
1 or 2 |
Very Good Jitter |
A |
| Direct VCXO |
2 |
1 |
1 or 2 |
Very Good Jitter |
B |
| Direct Oven |
3 |
1 |
1 |
Excellent Jitter |
C |
| Tuned Multiplication |
2 |
1 |
1 or 2 |
Periodic Jitter |
D |
| Discrete PLL |
2 |
2 |
2 or 3 |
Good Jitter |
E |
| Monolithic PLL |
1 |
3 |
2 or 3 |
Close in Jitter is Poor |
F |
Table 2
CONCLUSION
To correctly specify performance of frequency sources both jitter frequency and amplitude should be
considered. This requires an understanding of jitter, measurement techniques and their limitations.
Time spent to determine system needs will result in fewer problems and less time spent fixing those
problems later on. It will also determine a cost-effective approach for each application.
In this paper, we discussed the definition of jitter, the units used to describe it, and why jitter is
an important parameter. We also reviewed techniques used to measure jitter as well as applications and
typical performance based of various kinds of oscillators. The discussion is by no means complete,
but should give the reader enough information to understand the issues involved. Industry standards
were listed, as well as references for further reading. It is hoped that this paper is useful and
considered a good starting point for understanding and specifying jitter.
|