CO-441 HCMOS, ACMOS and FCT Clock Oscillators



CO-441

Features:
SPECIFICATIONS
Series CO-441: 4 Pin Dip
Frequency 1 Hz-200 MHz
Supply 5 Vdc ± 5%
(Available with 3.3 Vdc input below 20 Mhz)
Accuracy
(Maximum Error at 25°C)
CO-441A ±50 ppm
CO-441C ±25 ppm
CO-441D ±15 ppm
CO-441B ±10 ppm
CO-441E ±1 ppm*
*Settability via external capacitor; (<60 MHz only)
Temperature Stability

Improved accuracy/stability available on some models. For example, for ±7 ppm over 0°C to +50°C and for ±10ppm over 0°C to +70°C. Improvement is also available over wider temperature ranges. Please contact factory.
STANDARD: 0°C to +70°C: ±25 ppm
Option 1: -55°C to +85°C: ±50 ppm
Option 2: -55°C to +125°C: ±50 ppm
Option 5: 0°C to +50°C: ±5 ppm
Option 6: 0°C to +50°C: ±10 ppm
Option 7: -55°C to +125°C: ±100 ppm
*Option 9: -55°C to +200°C: ±300 ppm
(Option 9: above 20 MHz in CO-440 Series
*Specified stability includes initial accuracy:
do not specify A,B,C,D or E accuracy.)
Aging Rate
(typical after 30 days)
3 ppm first year
2 ppm/year thereafter
top of page



SCREEN TESTING OF ABOVE MODELS
SCREEN TEST MIL-STD-883
METHOD
Standard Options
CLASS
X
CLASS
D
CLASS
B
CLASS
S
Stabilization Bake
(150°C)
X X X Class S screen test requirements include 24 hour additional bake-out, 80 hour additional burn-in, thermal shock, PIND test and radiographic inspection in addition to Class B Screening. Has major cost impact.
Seal Test
(Gross and Fine)
1014, Cond A2 X X X
Temperature Cycling
(Thermal Shock)
1010, Cond B   X X
Burn-in, operating
160 hours @125°C
  X X
Acceleration
(5000g in Y1 axis)
2001, Cond A     X
top of page



Dimension in inches
 
Pinouts
Pin
1
7
8
14
Other
Function
*N/C
OV, case, gnd
Output
Supply +
N/C