SPECIFICATIONS
|
|
Series
|
CO-449: 4 Pin ½ DIP
|
|
Frequency
|
1 Hz-100 MHz
|
|
Output
|
HCMOS ≤ 50 MHz, ACMOS > 50 MHz
|
|
Supply
|
5 Vdc ± 5%
(Available with 3.3 Vdc input below 20 Mhz)
|
Accuracy (Maximum Error at 25°C)
|
A : ± 50 ppm, C = ± 25 ppm, D = ±15 ppm
B : ± 10 ppm, E* = ± 1 ppm
*Settability via external capacitor; (<30 MHz only)
|
Temperature Stability
Improved accuracy/stability available on some models. For example, for ±7 ppm over 0°C to +50°C and for ±10ppm over 0°C to +70°C. Improvement is also available over wider temperature ranges. Please contact factory.
|
|
STANDARD:
|
0°C
|
to
|
+70°C:
|
±25 ppm
|
|
Option 1:
|
-55°C
|
to
|
+85°C:
|
±50 ppm
|
|
Option 2:
|
-55°C
|
to
|
+125°C:
|
±50 ppm
|
|
Option 5:
|
0°C
|
to
|
+50°C:
|
±5 ppm
|
|
Option 6:
|
0°C
|
to
|
+50°C:
|
±10 ppm
|
|
Option 7:
|
-55°C
|
to
|
+125°C:
|
±100 ppm
|
|
*Option 9:
|
-55°C
|
to
|
+200°C:
|
±300 ppm
|
(Option 9: N/A above 20 MHz in CO-449 Series)
*Specified stability includes initial accuracy: do not specify A,B,C,D or E accuracy.
|
|
Aging Rate (typical after 30 days)
|
3 ppm first year 2 ppm/year thereafter
|
Screen Tests:
|
Class X: Seal test per MIL-STD-883,
Method 1014, Condition A2 (gross and fine)
stabilization bake @ +150ºC
|